Written by the ins.Cube product team, Guangzhou GROPE Furniture Co., Ltd.
Published 6 November 2026 · Last updated November 2026
Buying an office pod comes down to nine checks: occupancy, acoustic rating, ventilation, power and data, footprint, installation access, fire and emission compliance, warranty, and landed cost. A pod that passes all nine costs more up front and less over five years.
This guide replaces the three-point summary previously published on this page. It is written for facilities managers, workplace designers, and procurement teams who have to defend a purchase order, not just choose a colour.
The nine checks at a glance
| # | Check | Pass criteria |
|---|---|---|
| 1 | Occupancy | Comfort capacity matches the real use case; no single cabin claims more than six |
| 2 | Acoustics | Published dB reduction plus reverberation time, backed by an ISO 23351-1 test report |
| 3 | Ventilation | Airflow figure per fan and an inside/outside temperature difference, not just "has a fan" |
| 4 | Power and data | Voltage range, outlet mix, network option, and a whole-cabin load you can plan a circuit around |
| 5 | Footprint | Cabin dimensions plus door swing plus circulation and egress width |
| 6 | Installation access | Weight, door width, lift capacity, floor loading, crew size and assembly time |
| 7 | Fire and emissions | GB 8624 B1, E0 panels, ENF outdoor floor, GB/T 18883 air quality — with reports on file |
| 8 | Warranty and service | Written coverage by component, response time, and spare-parts availability |
| 9 | Landed cost | Unit price plus freight, installation, duties, and the 40HQ loading figure |
1. Does the pod hold the number of people you need?
Start with comfortable occupancy, not the number in the brochure headline. Catalogues in this category routinely advertise "4–6 person" cabins that seat four adults and a laptop each, and "6–8 person" cabins that seat six.
| Comfort capacity | Models | Realistic use |
|---|---|---|
| 1 | NS1, ins.Cube S1 one-person pod | Calls, focused work, single occupancy sessions |
| 1–2 | ins.Cube S2 focus pod, M1 | Pairing, interviews, one-to-ones |
| 2–3 | ins.Cube M2 collaboration pod | Three-person huddles, stand-ups |
| 2–4 | NL1 | Small project meetings |
| 4 | L1 | Four-person working sessions with screens |
| 6 | ins.Cube L2 meeting pod | Scheduled meetings up to six |
Two rules make this check usable. First, a single cabin tops out at six people; eight-person pods exist as a search term in the market, not as a specification in this range, so treat the number with suspicion. Second, buy for the 80% case: a six-person cabin used by one person for phone calls is wasted floor area, and a one-person cabin used for pair reviews creates a queue.
Ask the supplier for the internal dimensions, not just the external ones. L2 is 2,072 × 2,000 mm inside against 2,200 × 2,032 mm outside — the difference is the wall and door build-up, and it is where the sixth chair either fits or does not.
2. Is the acoustic claim backed by a report?
"Soundproof" is an adjective. A test report is evidence. The check has three parts: reduction figure, reverberation time, and the standard behind both.
Reduction. In this range, NS1 and NL1 are rated 28–32 dB; S1, M1, L1 and L2 are 30–35 dB; the S2 is ≥28 dB in Standard trim and ≥32 dB in Expert trim; the outdoor HL series is ≥30+3 dB. A 5 dB spread between models is normal, because panel area and door size change with cabin size.
Reverberation time. S, M and L series sit at 0.12 s, NL1 at 0.15 s, and the HL series at 0.20 s. This figure decides whether a call sounds natural or hollow to the person on the other end, and it is the number most suppliers leave out of their datasheets.
The standard. Our acoustic performance is documented in an ISO 23351-1 acoustic test report from SGS, grade E. Ask any supplier for the report page, the laboratory, and the grade — not a marketing claim. If the answer is a brochure adjective, the claim is unverifiable.
Also ask what the Standard and Expert trims actually change. In the S2, Expert adds a laminated rear glass build and a heavier steel gauge, which is where the extra 4 dB comes from; it is not a different acoustic core.
3. Is the pod actually ventilated?
A sealed cabin with no airflow is an acoustic success and a comfort failure. Two numbers settle the question.
Airflow per fan. Our ventilation uses a 120 × 120 × 25 mm axial fan at 1,800 rpm, drawing 14 W and moving 66 CFM, with a fan noise level of 38 dB. Cabin airflow is an upper-in, lower-out dual circulation, so the cabin runs at neither positive nor negative pressure.
Temperature difference. Measured inside-to-outside difference stays within 2 °C, which is the practical test of whether a cabin becomes a greenhouse in summer. If a supplier cannot state a temperature difference, they have not measured one.
For outdoor units the numbers change: eight quiet fans move 280 m³/h total, completing a full air change roughly every two minutes. That scale is specific to the HL series and should never be quoted for an indoor pod.
Finally, check the operating envelope. Indoor models are specified for 15–30 °C ambient, relative humidity ≤60%, and at least 30 cm of clear space around the cabin for heat dissipation. A pod squeezed into a 40 cm alcove with no clearance will run hot no matter what the airflow figure says.
4. Are power and data mapped before delivery?
Electrical surprises are the most common cause of a delayed handover. Confirm four things before signing.
Voltage. The cabin accepts a wide 110–220 V supply at 50/60 Hz, with sockets rated 100/240 V — which covers most of Europe, the Middle East, and North America without a transformer.
Outlet mix. Standard fit is two power outlets plus a 15 W USB port and a 20 W USB-C port. That is enough for a laptop, a phone, and a second device; it is not enough for a space heater, which is prohibited inside the cabin in any case.
Data. A Cat 6 network module with internal and external sockets is an option on several models. If the pod is going into a workplace with wired desks, specify it at order time — retrofitting a network port into an acoustic panel is not a site task.
Whole-cabin load. An indoor pod draws about 250 W at full load, which is roughly a desktop plus a monitor. Outdoor pods draw 854 W in standard configuration with the air conditioning running. Size a dedicated circuit from those figures, add RCD/GFCI protection, and do not share the circuit with site tools.
5. Does the footprint match circulation and egress?
Floor area is the easy part; circulation is where layouts fail. Published footprints run from 1.06 m² for the S1 to 4.47 m² for the L2, with M1 at 2.09 m², M2 at 2.49 m² and L1 at 3.37 m².
Add three allowances on top of the cabin:
- Door swing and standing room. A person opening the door needs roughly a metre of clear space in front of it, and that space cannot also be a walkway.
- Ventilation clearance. At least 30 cm around the cabin for heat dissipation on indoor models.
- Egress width. A pod placed against the only route out of a zone is a fire-planning problem regardless of its acoustic rating.
The practical test is a scaled plan with the door drawn open. If the open door blocks a walkway, move the pod rather than shrinking the walkway.
6. Can the pod physically get into the building?
Weights in this range run from 220 kg for the NS1 to 755 kg for the HL2, with 532 kg for the six-person L2. That is furniture-scale mass, not parcel-scale, and the access route decides whether installation is a morning or a month.
Check, in this order:
- Gate and door width against the largest panel, not the assembled cabin.
- Lift dimensions and rated load — a 500 kg cabin plus two installers plus a pallet truck exceeds many passenger lifts.
- Floor loading at the final position; if the pod goes on a raised floor or a mezzanine, confirm the point loads with the structural engineer.
- Crew size and time — S series needs two people for 30–45 minutes; M1 needs three people for about 1.5 hours; L1 needs four people for 2–3 hours; the HL series needs four people for 3–4 hours.
- Route surface — carpet tiles lift under castors, and thresholds need ramps. A pod that arrives before the ramps becomes a corridor obstruction.
If any of these answers is marginal, the modular six-part build is the workaround: panels and glass can be carried separately and assembled in place, which is how pods reach upper floors without a crane.
7. Does it meet fire and emission requirements?
Three certificates cover most procurement questionnaires, and each answers a different question.
| Requirement | Standard | What it covers |
|---|---|---|
| Fire performance | GB 8624-2012 B1 | Combustion behaviour of the panel build |
| Formaldehyde emission | T/CADBM 3-2018 E0 | Interior panel emission class |
| Outdoor floor panel | ENF grade | Stricter than E0, used on the HL series floor |
| Indoor air quality | GB/T 18883-2002 | Air quality assessment method |
| Acoustic panels | EN 15012 + EN 12149 | Absorber and facing performance |
Two cautions. First, do not accept an absolute formaldehyde-free claim — no panel product achieves it, and the claim is a red flag in a specification response. Second, ask whether the reports cover the panel as supplied, not a generic material sample; a certificate for the raw board is not a certificate for the finished cabin.
Our certificates are collected on the acoustic and emission certificates page.
8. What does the warranty actually cover?
Warranty is the check most often reduced to a number in a tender table, and the number is usually the least useful part. Ask four questions instead.
- What is covered, by component? Structure, glass, door hardware, ventilation fans, lighting, and air conditioning age differently and should be listed separately.
- What is excluded? Consumables, filters, damage in transit, and installation by a third party are common exclusions.
- What is the response time? A warranty period without a service level is a promise with no clock attached.
- Where do spare parts come from? A fan or a door gasket that ships in six weeks turns a one-hour repair into a six-week outage.
Coverage on the ins.Cube range is set per contract, with the cabin and the electrical components warranted separately. We deliberately do not publish a single headline number, because a structural warranty and an electrical warranty are different instruments and should be read as such. Service arrangements are listed on the frequently asked questions page.
9. What is the true landed cost and lead time?
The unit price is the smallest part of the decision. Landed cost has five layers, and the last two are the ones buyers forget.
| Layer | What to confirm |
|---|---|
| Unit price | Sample pricing basis, trim level, included options |
| Freight | FOB, CIF or DDP; port pair; consolidation |
| Container utilisation | 40HQ loading per model — see the table below |
| Installation | Crew size, hours, travel, ramps, lift hire |
| Duties and compliance | HS code, import duty, any local conformity work |
Published pricing for this range is sample pricing, limited to one unit per model and available on request. The S2 is listed at USD 1,750 in Standard trim and USD 2,600 in Expert trim. Treat that as a reference point for budget shaping, not as a quotation.
| Model | 40HQ loading |
|---|---|
| NS1 / S1 | 42 (double deck) |
| S2 | 36 (double deck) |
| M1 | 24 (double deck) / 17 (single deck) |
| M2 | 24 (double deck) / 15 (single deck) |
| NL1 / L1 | 15 (single deck) |
| L2 | 20 (double deck) |
| HL1 | 15 (single deck) |
| HL2 | 20 (double deck) |
Container utilisation is where a small order quietly becomes expensive: 15 units of L1 fill a 40HQ, so a three-unit pilot order carries almost the same freight as a fifteen-unit one. If the pilot is real, plan the follow-on volume before booking the container.
For export terms and consolidation practice, see the OEM and CIF guide.
Frequently asked questions
How long is the lead time?
Lead time depends on model, quantity, trim level and Incoterm, so it belongs in the quotation rather than on a web page. Ask for a production schedule and a sailing date separately — a single "8 weeks" figure usually hides which half is which.
Can we specify colours?
Seven cabin colours and three carpet colours are standard. Project-specific colours are possible subject to a minimum order quantity, and the powder-coat batch is the constraint, not the fabric.
How many people does installation need?
Two people for the S series, 30–45 minutes; three for M1, about 1.5 hours; four for L1, 2–3 hours; four for the HL series, 3–4 hours. No specialist trades are required, but the gasket sequence should be owned by one person.
What does the warranty cover?
Coverage is set per contract, with the cabin structure and the electrical components underwritten separately. Ask for the clause that lists components, exclusions and response times, and keep spare-parts lead times in the same document.
How many pods fit in one 40HQ?
Between 15 and 42 depending on model: 42 for NS1 and S1, 36 for S2, 24 for M1 and M2 double-deck, 15 for NL1, L1 and HL1, 20 for L2 and HL2. Plan freight per unit from the model you actually intend to buy.
Request the procurement checklist
We maintain a 20-question version of this guide for tender documents, covering floor loading, gasket specification, report references and service levels. Request the 20-question procurement checklist and we will send it with the current specification sheet for the models you are evaluating.
For the definitional background, start with what is an office pod; for outdoor installations, use the outdoor pod guide.